Open System Settings from the profile menu at the bottom of the sidebar. "HVAC defaults and global system preferences for your company." Save Changes at the bottom saves only the parts you changed.

HVAC Calculator Default Factors

Leave a field empty to use the default shown. Needs User Management or Operation Management.

FieldDefaultNote
Glass Factor0.56Applies to all glass direction rows; at most 1.0
Wall Factor0.36Applies to all wall direction rows
Roof Factor0.55Applies to roof sun and shaded rows
Partition / Ceiling / Floor Factor0.32Applies to partition, ceiling and floor rows
All Glass Partition Factor1.13Applies to the all-glass row in the partitions tab
Selected ADP (°C) or Selected ADP (°F)Shown on screenFollows the unit system. Used only when the ESHF solver cannot converge.

System Preferences

Needs User Management. Currency and financial year need Owner or Admin.

FieldWhat to chooseNote
TimezoneNot editable hereLink: Change it in Settings, Time zone
Date FormatMM/DD/YYYY, DD/MM/YYYY, YYYY-MM-DD, DD.MM.YYYY or YYYY/MM/DDShows a preview of today
CurrencyThe company currencyGreyed out once documents exist; the reason shows under it
LanguageEnglishAlways greyed out
Unit SystemSI (Metric) or Imperial"Measurement system used across the application (Imperial or Metric)." Sets the default unit of new enquiries and calculators.

Invoice Numbering

Needs User Management.

FieldWhat to enterDefault
PrefixFor example INVINV
PatternTokens such as {PREFIX}-{FY}-{SEQ}; see Invoice numbering: tokens and example patternsShown on screen
Delivery challan prefixOne to four letters or digitsDC
Start numberThe first number in the sequence1
Sequence digits0 to 124
Reset sequenceNever, Every financial year or Every monthEvery financial year
Financial year startsJanuary to DecemberApril. Owner or Admin. Locked once an invoice is issued in the current financial year.
Start for each branchA start number per branchOnly when the pattern has {BRANCH}

The line "Next invoice preview" shows the next number. "Changing the Start number or Reset mode restarts the sequence; other edits keep the running count."

Work Stages Configuration

Needs User Management.

FieldWhat to chooseNote
Enable Custom Stage SelectionOn or off"When ON, only the stages you select below may be included in new projects."
Select stages to include in new projectsHeat Load Calculation, Site Survey, System Type Recommendation, Pipe Recommendation, Ductwork Planning, Ventilation & Fresh Air Planning, Material Estimation & BoM, Inventory Management, Installation Management, System Testing & Balancing, Inspection & Compliance, Commissioning & HandoverStages already used in projects are locked