Stages by firm type
Your firm type is set on Modules & Firm Type. See Change your firm type. Stages are listed in the order they appear on a project.
| Stage | Design & Consultation | Execution & Installation | Design-Build (both) |
|---|---|---|---|
| Heat Load Calculation | Yes | No | Yes |
| Site Survey | Yes | Yes | Yes |
| System Type Selection | Yes | No | Yes |
| Pipe Sizing | Yes | No | Yes |
| Ductwork Planning | Yes | No | Yes |
| Ventilation & Fresh Air Planning | Yes | No | Yes |
| BoQ | Yes | Yes | Yes |
| Material Allocation | No | Yes | Yes |
| Installation | No | Yes | Yes |
| System Testing & Balancing | No | Yes | Yes |
| Inspection & Compliance | No | Yes | Yes |
| Commissioning & Handover | No | Yes | Yes |
Pipe Sizing, Ductwork Planning and Ventilation & Fresh Air Planning depend on the project's system type. Until the system is confirmed on the System summary panel of AC Unit Recommendations, they read "Awaiting system selection". Once it is confirmed, a stage the system does not need is hidden, or reads "Not applicable to selected system" if it already holds work. See A stage says "Awaiting system selection" or "Not applicable to selected system".
Limit the stages for your company
On System Settings, under Work Stages Configuration, the switch Enable Custom Stage Selection limits new projects: "When ON, only the stages you select below may be included in new projects." Stages already used in existing projects are locked and cannot be removed. See Choose which work stages new projects can include.
Building Model and Duct Layout
| Stage | When a new project gets it | Where it goes |
|---|---|---|
| Building Model | Your company has the Building Model module switched on, and DuctArchitect has turned it on for you | First in the list |
| Duct Layout | Your company has the Duct Layout module switched on, and DuctArchitect has turned it on for you | After Pipe Sizing |
Both modules start off for every firm type. See Switch a module on or off. If you switch a module off later, projects keep the stage; only its tool button hides.
A project created before Duct Layout was switched on can get the stage afterwards. See Add the Duct Layout stage to an older project. There is no such button for Building Model.
The preview on Add Project
Under Load & System, Add Project shows "Stages this project will get", with a count and the stage titles. Some titles carry " (if ducted)". The preview does not follow your firm type or Work Stages Configuration, and it always lists Building Model. So the new project can have fewer stages than the preview shows. See The Duct Layout or Building Model stage is missing.
Retired and renamed stages on older projects
| What you see | What it is |
|---|---|
| Design Drawings | A retired stage. New projects have not got it since 19 September 2026. Older projects still show it, with an upload area only, and it can still be finished. |
| Equipment Procurement | A retired stage, hidden on every project. The Kanban board can still show a column for it. |
| "Building Drawing" in the stage panel title | The old name of Building Model. The stage list shows Building Model. |
| "Procurement" in the stage panel title | The old name of Material Allocation. The stage list shows Material Allocation. |