What it is
AC Unit Recommendations is where you choose the equipment for one project: AC units, VRF indoor and outdoor units, or chilled water or hot water plant. It works against the project's heat load and offers equipment from your own items. The page has no sidebar entry. It opens only from a project, for example with Open Recommendations on the System Type Selection stage. See Open AC Unit Recommendations for a project.
Capacity on this page is always in TR and airflow in CFM, whatever your company's unit system. Spaces that need heating only show their load in kW.
An item is offered only when its category is AC Systems and its equipment type is set. Items without an equipment type show "Type not set". Items are set up on the Items page, in the Catalog and inventory module. See Set the equipment type and capacity of AC units.
How it moves
-
Confirm the system. The System summary panel shows the system type from the project setup and whether the Ductwork Planning and Pipe Recommendation stages are needed. Confirming it is what lets those stages open. See Confirm the project's system.
-
Read the sizing basis. The blue sizing banner says how the equipment is sized:
Headline System type Form on the Choose card "Units are sized per space" Room splits Units per space table "Indoor units per space, outdoor units on the block load" VRF / VRV Units per space table with Outdoor units "One unit sized on the block load" Ducted DX Load chips and card grid "Plant sized on the block load" Chilled water Plant duty picker and fan coil units "Plant sized on the block heating load" Hot water heating Plant duty picker and fan coil units "Equipment sizing" No system type set Load chips and card grid Under it, each space shows its load in TR, "heating only", or "-".
-
Choose the equipment on the Choose card. Nothing is saved yet. A unit proposed on the heat load results shows as "Proposed on heat load: [text]" with a "from heat load" badge to confirm.
-
Check the verdicts in the footer: capacity and airflow "met", short or oversized.
-
Save the selection. Save selection stores it on the project's System Type Selection stage, replacing what was saved before. See Save your equipment selection.
The saved selection is then read by:
- the Selected AC systems panel on the System Type Selection stage. See Review the selected AC systems on the project;
- Duct Sizing, for its external static pressure and airflow. See Generate the duct tree from heat load;
- the BoQ. See Build a project's BoQ;
- Material Allocation, where the chosen items are marked as recommended, in the Catalog and inventory module. See Allocate materials to a project;
- the heat load results, which show what was chosen for a space.
Who is involved
| Role | What they do |
|---|---|
| Anyone with Inventory Management (by default Owner, Admin and Manager) | Opens the page and chooses equipment. |
| The same, with Edit on Projects and a role other than Technician or Worker | Confirms the system and saves the selection. |
| Anyone who can see the System Type Selection stage | Sees the selected AC systems on the project. |
| Whoever looks after your items | Sets the AC Systems category and the equipment type on each item, so it is offered here. |