Before you start

  • You need Operation Management, and Edit on Duct and load calculations.
  • Duct Sizing is open from a project. See Size the ductwork for a project.
  • The project has a saved heat load calculation. See Calculate the heat load for a project.
  • For a design friction rate, the project has AC systems selected on its System Type Selection stage. See Save your equipment selection.

Steps

  1. In the Duct tree card, select ⚡ Generate from heat load. The box "Generate duct tree from heat load" opens: "Loading heat load zones…".

    Step 1. The Generate duct tree from heat load box with the zone table.
    Step 1. The Generate duct tree from heat load box with the zone table.
  2. Check the source line: "Heat load: [project]" with "[number] heat-load calculation(s) · [number] zone(s)".

  3. Check the equipment line from the System Type Selection stage, the line "Main duct sized for [value] (sum of zone loads).", and the zone table (Zone, Floor).

  4. Enter the measured longest run: "Enter the measured longest run. The default is a placeholder." Reset to layout value puts the layout's value back.

  5. Read the component pressure losses and the cooling capacity and airflow checks.

  6. Select Generate 1 main + [number] branch(es).

Result

The message "Generated [main] + [number] branch(es) from heat load" shows. The tree has one main duct, sized for the sum of the zone loads, and a branch per zone, each tagged "From heat load · [name]". Size each duct and apply a size. See Size a duct by friction loss or by velocity.

Selecting ⚡ Generate from heat load again later compares the tree with the heat load: "Heat load changed for [number] zone(s), review the flagged ducts." or "Heat load matches the current tree, nothing to reconcile."

If something is different

  • "No saved Heat Load Calculation found for this project yet.": see Generate from heat load says no heat load calculation was found.
  • "Cannot generate: [number] zone(s) need(s) a usable airflow": see "Cannot generate": a zone needs a usable airflow.
  • "No AC system selected for this project.": "No equipment means no external static pressure, so no design friction rate can be derived." Select Pick the AC systems for this project → to choose them. See Open AC Unit Recommendations for a project.
  • "Using a default ESP of [value] [unit] until an AC system is selected.": the box sizes with a default external static pressure until AC systems are selected.
  • "Equipment nameplate [value] [unit] is not used to size ductwork: every duct, including the main, is sized from the load it serves.": the main duct is sized from the zone loads, not from the unit's rating.
  • No Generate from heat load: Duct Sizing was opened without a project.