Duct design
Duct Sizing: build the duct tree, size each duct, save and export
Build a tree of main ducts and branches, size each one by friction loss or by velocity, and pick a rectangular size. Inside a project the airflow can come from the heat load, and the sizing saves to the project.
Build the duct tree
- DoAdd main ducts and branchesAdd main ducts one at a time or five at once, add branches under the selected duct, and duplicate a duct you have set up.
- DoMove, view or clear ducts in the treeDrag a duct under another to re-parent it, see the whole tree as a diagram, or remove every duct and start again.
Size ducts
- DoSize the ductwork for a projectOpen Duct Sizing from the project's Ductwork Planning stage, build or generate the duct tree, size each duct and apply a rectangular size. The sizing saves to the project.
- DoPick a rectangular size and lock itPick a rectangular duct size from the equivalents for the selected duct, or enter your own width and height, then apply it so the size stays fixed. Unlock it to change it later.
- DoSize ducts without a projectUse Duct Sizing on its own from HVAC Tools to size ducts, and change the unit system. Without a project nothing is saved and there is no heat load to generate from.
Use heat load airflow
Save and export
- DoSave your duct sizingInside a project, Duct Sizing saves as you work and shows whether everything is saved. Save it yourself, and leave safely with Back.
- DoExport duct sizing resultsSee every duct's results in one table and export them as CSV from Duct Sizing, or download the project's duct results as Excel from the Ductwork Planning stage.
How it works
Fix a problem
- FixThe unit toggle is greyed outIn Duct Sizing opened from a project, the Imperial / Metric toggle cannot be changed. The project's unit system decides the units.
- FixGenerate from heat load says no heat load calculation was foundThe Generate duct tree from heat load box says there is no saved heat load calculation for the project. Calculate the project's heat load first.
- Fix"Ductwork does not apply to this project"Duct Sizing refuses to open for a project whose system has no ducted units. Work saved earlier is kept.
- FixA duct shows the "Heat load updated" bannerA duct generated from the heat load says its zone now needs a different airflow. The heat load changed after the duct was sized; re-size it or keep it.
- FixSave says the plan is not active, or Duct Sizing sends me to BillingDuct Sizing opens Billing, an upgrade box opens from the sidebar, or Save opens a plan box, because your company's plan is not active or has reached its limit.
- FixChanges may not be saved when I leaveSelecting Back in Duct Sizing asks whether to leave anyway, because the automatic save failed. Stay and save first.
- FixI can't change a duct's sizeA duct's size or inputs cannot be changed because its size is locked, because it has children, or because you have view-only access.
- FixThe duct drawing screen only shows a noticeThe old duct drawing screen now shows only a notice that duct drawing lives in each project's Duct Layout stage, which most companies do not have yet.
- FixDuct Sizing is missing or opens Access DeniedThe sidebar has no Duct Sizing, or Open Duct Sizing on a project opens Access Denied. Duct Sizing needs Operation Management and the HVAC Tools module.
- Fix"Cannot generate": a zone needs a usable airflowGenerate from heat load is refused because one or more heat load zones have no usable airflow. Calculate those spaces, then generate again.
- FixThe velocity is outside the recommended rangeThe velocity gauge says the duct is below or above the recommended range, or a warning banner shows on SI. What each message says and how to change the size.
Other modules
- Getting startedSign in, your account, the dashboard and notifications
- Company and usersCompany profile, GST and branches, users, roles, permissions, modules and imports
- CRMClients, enquiries from New to Converted, and CRM reports
- ProjectsProjects, their workflow stages, to-dos, team and files
- Heat loadDesign conditions, space-by-space heat load, results in TR and downloads
- AC unit recommendationsConfirm the system, choose AC units or plant from your items, and save the selection to the project
- Quotations and BoQQuotations from draft to accepted, project and standalone BoQs, templates and BoQ settings
- Catalog and inventoryItems and brands, stock in your warehouses, project materials, stock out with delivery challans, and returns
- PurchaseSuppliers, purchase orders, deliveries, returns to suppliers, and what you owe and pay
- Material requestsAsk for material for a project, a to-do or a service job, get it approved, then issue or order it
- Service and maintenanceAMC, service and warranty contracts, visits, technicians, billing and machines
- FinancialInvoices, payments, expenses, job costing, expense claims and financial reports
- AccountsChart of accounts, ledgers, vouchers, banking, posting, Tally and financial statements
- HRMSEmployees, attendance, leave, salary structures and payroll
- Worker appThe phone app and the Associate Portal for field workers and technicians
- Help and supportHow to use this site and how to reach us