What it is
Duct Sizing sizes a project's ductwork one duct at a time. You open it from HVAC Tools › Duct Sizing, or from a project's Ductwork Planning stage with Open Duct Sizing. The screen has three cards:
- Duct tree on the left: the main ducts and their branches, with the totals.
- Air data in the middle: the selected duct's inputs.
- Results on the right: the round diameter, velocity, pressure loss and the rectangular sizes.
"Results update as you type: no Calculate button needed. Pick a size on the right to apply it to this duct."
How it moves
- Build the tree. Add main ducts, then branches under them. Drag a duct onto another to make it a child: "Totals & inherited rates update automatically."
- Set the airflow. Each duct's air quantity (CFM or L/S) comes from one of three places, shown by its tag:
- "Σ Sum of children": a duct with children adds up their air quantities and cannot be typed. It reads "Calculated from [number] children".
- "From heat load · [name]": the air quantity came from a heat load zone, with ⚡ Generate from heat load.
- "Manual override": you typed it.
- Choose how to size it. With Size by friction loss: "Equal-friction method: you set the friction rate, velocity is calculated." With Size by velocity: "You set the velocity, friction loss is calculated." A new branch takes its parent's friction loss.
- Pick a size. The results list rectangular equivalents. Pick one, then select Apply size to duct. The size is locked: the duct shows Locked and Size Locked. Unlock size frees it again.
- Follow heat load changes. If the project's heat load changes after you generated the tree, a duct shows "Heat load updated: [zone] now needs [number] [unit]. This duct is sized for [number] [unit]." Re-size to [number] [unit] applies the new airflow. See A duct shows the "Heat load updated" banner.
- Save. Inside a project the sizing saves to the project as you work, and with Save. Without a project nothing is saved.
The units come from the project's unit system inside a project: Imperial (CFM, in/100ft, FPM, inches) or SI (L/S, Pa/m, m/s, mm). Without a project they follow your company's preference, or your company's country.
Who is involved
| Role | What they do |
|---|---|
| Anyone with Operation Management and View on Duct and load calculations (by default Owner, Admin and Manager) | Opens Duct Sizing and reads the results. |
| The same, with Add or Edit on Duct and load calculations | Builds the tree, sizes and locks ducts, and saves to the project. With View only, the inputs are read only. |
| Whoever calculates the heat load | Provides the airflow for Generate from heat load. See Calculate the heat load for a project. |