  2. HVAC Tools
  3. Unit Converters
  4. GPM to L/s

US GPM to L/s Converter

Convert US gallons per minute to litres per second for HVAC pump checks and chilled water flow calculations. Use the conversion factor and formula to compare flow rates accurately across US customary and metric units.

Type in either field. The other one updates as you type.

Keep HVAC Projects Organized Beyond Calculations

Flow values are only one part of an HVAC job. DuctArchitect helps keep project tasks, employee activity, material records, and job updates organized as work progresses.

  1. 01

    Project Planning & Workflow: Keep project stages, tasks, and timelines organized.

  2. 02

    Tracking: Monitor employee activity and location during field operations.

  3. 03

    Project Files & Activity: Keep drawings, documents, and project updates connected to each job.

  4. 04

    Project Materials: Organize material requirements and usage by project.

Start 14-Day Free TrialBook a Demo

Start your 14-day free trial, no credit card needed.

GPM to L/s formula

L/s = US GPM × 0.063090196

US GPM = L/s ÷ 0.063090196

The factor is 0.063090196 L/s for each 1 US GPM. Going the other way, 1 L/s is 15.850323 US GPM.

GPM to L/s reference table

US gallons per minute converted to litres per second
US GPML/s
50.315451
100.630902
251.57725
503.15451
1006.30902
20012.618
30018.9271
50031.5451
1,00063.0902
2,000126.18

Where this conversion is used

Chilled water, condenser water and hot water flow rates are given in US GPM on US pump curves, coil selections and chiller data, and in L/s on the metric schedules used across India and the Gulf. Use this conversion for pump schedules, coil and valve selection, and water balancing reports. This page uses the US gallon. The imperial (UK) gallon is larger, 4.54609 L against about 3.785 L, so check which gallon a data sheet means.

Worked example

A chiller data sheet shows a chilled water flow of 240 US GPM and the pump schedule is in L/s.

240 US GPM × 0.063090196 = 15.1416 L/s

Schedule the pump for about 15.14 L/s.

Common mistakes

  • Using the imperial gallon. Older British data may be in imperial GPM, which is about 20 percent more flow for the same number.
  • Confusing L/s with L/min or m³/h. One litre per second is 60 litres per minute.
  • Mixing air and water units on the same sheet. L/s is used for both airflow and water flow, so label which one it is.

Related HVAC Tools & Resources

ConverterPSI to kPa Converter for HVAC Pressure ChecksConvert pressure readings between psi and kPa when checking HVAC specifications, commissioning notes, or test results that use different units. Keep values consistent for measurement comparisons.Open converter
ConverterCFM to CMH Converter for Airflow ChecksCompare airflow in CFM and CMH when reviewing fan data, ventilation schedules, or HVAC equipment specifications that use different volume units. Keep calculations consistent across project documents.Open converter
ConverterImperial to SI U-Value ConverterCompare imperial and SI U-values in insulation data, envelope specifications, or building performance documents. Confirm the unit system before comparing thermal transmittance figures.Open converter
ConverterkW to BTU/hr Converter for HVAC CapacityConvert kW to BTU/hr when checking HVAC capacity ratings, equipment schedules, and datasheets. Matching units makes it easier to compare cooling or heating capacity across product documents.Open converter
CalculatorFree HVAC Duct Size CalculatorEstimate duct dimensions from airflow requirements with the free HVAC duct size calculator. Use results as a design aid, then confirm friction loss and project requirements before installation.Open calculator
FeatureDuctArchitect Features for HVAC OperationsManage HVAC leads, project tasks, field teams, inventory, service contracts, invoicing, and accounts in one platform. Review the features to see how DuctArchitect supports daily operations.Explore feature
GuideHVAC Load Calculation Software for Design PlanningSee how HVAC load calculation software supports equipment sizing by assessing building details, heat gains, ventilation, and design inputs. Review key methods before choosing a calculation workflow.Read guide

Frequently asked questions

How does GPM to L/s conversion work for HVAC flow checks?

Multiply US GPM by 0.0630902 to get L/s. This converts gallons per minute to litres per second, with 10 US GPM equal to approximately 0.631 L/s. A US GPM to L/s Converter applies the factor automatically.

How many US gallons per minute equal 1 L/s, and how do you reverse the calculation?

One litre per second equals approximately 15.8503 US GPM. For the reverse l/s to gpm conversion, multiply the L/s value by the lps to gpm conversion factor of approximately 15.8503 for US gallons.

How do US and Imperial gallons compare when converting HVAC flow rates?

No, a US gallon and an Imperial gallon are different sizes. One US gallon equals 3.785412 litres, while one Imperial gallon equals 4.54609 litres. This US GPM vs Imperial GPM distinction matters when comparing pump schedules and equipment specifications.

How can you convert L/s to L/min or m³/h for HVAC calculations?

Multiply L/s by 60 to get L/min, or by 3.6 to get m³/h. For example, 2 L/s equals 120 L/min or 7.2 m³/h. When checking a GPM to m³/h conversion chart, confirm that it uses US gallons.

Why do HVAC pump schedules use both US customary and metric flow units?

Pump schedules may follow different project specifications, manufacturer documents, or unit conventions. Convert values to the same unit and confirm the gallon type before comparing them. A US GPM to L/s Converter helps standardize flow values, while a chilled water flow rate converter supports flow comparisons for chilled water systems.

What should you check before using a flow value for pump selection?

Confirm the flow unit and gallon type, then check the required pump head and manufacturer performance data. An HVAC pump flow calculator may support flow checks, but it does not replace pump selection based on system requirements. Pressure and motor power require separate checks, such as a psi to kPa calculator or an HP to kW converter.

Can flow conversion confirm that a hydronic system is balanced?

No, unit conversion changes the way flow is expressed, not the actual flow distribution in the system. A hydronic balancing flow calculator may support calculations, but proper balancing also requires measured flow rates, design targets, and suitable adjustment procedures.

Does a flow converter replace duct sizing or other HVAC calculations?

No, a flow converter changes flow units only. A Free HVAC duct calculator serves duct-sizing needs, while pump selection and hydronic balancing require their own calculations and design inputs.

Sizing a real project? DuctArchitect handles heat load and duct sizing for the whole job.

Start Free TrialTry the free duct size calculator
DuctArchitect Logo

DuctArchitect is the HVAC ERP for contractors and consultants, helping you design, calculate, and manage every project without switching between disconnected apps and manual paperwork.

Contact Us

USA Office

4138 Sunnyview Rd NE, Apt 99
Salem, OR 97305
United States

+1 (971) 225-4560
India Office

Manohar 5th Floor CYB -6 RIICO Cyber Park near Saras Dairy, Heavy Industrial Area Phase II Jodhpur, Rajasthan 342003 India

+91 9251643282

Mon-Fri 8AM-6PM IST

support@ductarchitect.com

We respond within 2 hours

Say hello

We'll take it there, so drop a message and your email.

Privacy
Help
Terms
Cancellation Policy
Refund Policy
© 2026 DuctArchitect • Empowering HVAC Excellence